Skip to main content

Glass type

Coated glass (low-emissivity, solar control and self-cleaning)

Glass with a thin coating on one face: low-emissivity coatings keep heat in, solar control coatings keep the sun's heat out, and self-cleaning coatings help rain wash dirt away.

In our catalogue today

Order it cut to size

Where it is used

  • Double-glazed units and roof lights
  • Conservatories
  • Windows facing the sun

Toughening and processing

Toughening
Most coated glass can be toughened before it is glazed; the coating faces the side the unit's make-up names.
Processing
The coated face is marked and faces the cavity or the weather as the unit's make-up says.

Care

  • Clean the coated face gently with water and a soft cloth; abrasive cleaners remove the coating.

Standards

StandardWhat it covers
BS EN 1096Glass in building. Coated glassGlass with a surface coating: low-emissivity, solar control and self-cleaning coatings.
BS EN 572Glass in building. Basic soda lime silicate glass productsFloat glass (part 2) and patterned glass (part 5): the base glass every other product starts from, its dimensions and quality.
BS EN 1279Glass in building. Insulating glass unitsSealed double and triple glazed units: their durability, gas retention and marking.