Fixed glass roof lights for flat and pitched roofs: sealed double-glazed units with a toughened outer pane and a laminated inner pane, so broken glass cannot fall into the room. Made to the size of your opening, with the slope the roof needs to shed water.

A fixed glass roof light letting daylight into a kitchen extension

At a glance

Glass
Sealed double-glazed units: toughened outer pane, laminated inner pane
Toughening
Outer pane toughened to BS EN 12150-1; inner pane laminated (BS EN ISO 12543).
Holes and cut-outs
None: the unit sits on its kerb
Sizes
Made to your opening and kerb
Priced
By hand, from your design or drawings

Where it is used

  • Flat roof extensions
  • Kitchen and living room roofs
  • Lightwells and stairwells
  • Pitched roofs

How it is priced

Send us the opening sizes or the drawings. Roof lights are priced by hand on a written quotation, with the unit's make-up stated.

What we supply

Unit make-up

Outer pane
Toughened glass, often with a coating that reduces heat loss or solar gain.
Inner pane
Laminated glass, so it holds together overhead if it breaks.
Cavity
A sealed gap between the panes, usually gas-filled.

Processing and the build-up

Sealed units
Insulating glass units to BS EN 1279.
Overhead glass
The lower pane is laminated (BS 5516-2), so broken glass stays in place.
Slope
Flat roof lights sit on an upstand that gives a fall, so rain runs off the glass.
Made to measure
Toughened glass cannot be cut, drilled, notched or edge-worked after it is toughened. Every size, hole and cut-out is fixed on the drawing before the glass is made.
6 mm toughened outer pane16 mm sealed cavity3 mm0.8 mm interlayer3 mm28.8 mmSection through the glass (layers drawn thicker than scale where thin)
Section through a typical double-glazed roof light unit: 28.8 mm overall.

Regulations

  • Approved Document L (conservation of fuel and power)

    A new or replacement roof light or window must meet the limiting U-value set in Approved Document L. The U-value comes from the whole unit's make-up and frame, not from the glass alone.

    England. Roof lights, windows and doors in heated buildings.

  • Approved Document A (structure)

    A floor, roof or canopy, and the glass in it, must carry the loads of its use safely. The project engineer sets the load class from BS EN 1991-1-1 and confirms the glass and its supports.

    England. Walk-on glass, roof lights and canopies.

Installation

  • Build the kerb or upstand level, square and to the size on our drawing, with the fall the roof needs.
  • Set the unit on the gaskets or setting blocks shown; the edge seal must not sit in standing water.
  • Weatherproof the junction with the roof covering before the room below is finished.
  • A fixed roof light is not for walking on unless it is made and marked as walk-on glass.

Care and cleaning

  • Clean the outside from a safe position with a long-handled squeegee, never by standing on the glass.
  • Clear leaves and debris from the glass and the roof around it so water drains.
  • Never use pressure washers on the edge seals.

Questions

Can I walk on a roof light?

Only if it is made as walk-on glass. A standard roof light is not designed to be stood on.

What U-value will it have?

The U-value depends on the whole unit's make-up and frame. Approved Document L sets the limit a new roof light must meet; the quotation states the unit's make-up.

Why is the inner pane laminated?

Overhead glass should hold together if it breaks, so nothing falls into the room (BS 5516-2).

Standards that apply

StandardWhat it covers
BS EN 1279Glass in building. Insulating glass unitsSealed double and triple glazed units: their durability, gas retention and marking.
BS 5516-2Patent glazing and sloping glazing for buildings. Code of practice for sloping glazingGlazing laid at a slope or overhead, such as roof lights and canopies: why the lower pane should hold together if it breaks.
BS EN 12150-1Glass in building. Thermally toughened soda lime silicate safety glass. Definition and descriptionWhat toughened safety glass is, its fragmentation test, flatness and edge work, and the limits for holes and notches. Every toughened pane carries a mark naming the standard.
BS EN ISO 12543Glass in building. Laminated glass and laminated safety glassLaminated glass: two or more panes bonded with an interlayer that holds the pieces together if the glass breaks. Part 2 covers laminated safety glass.
BS EN 1096Glass in building. Coated glassGlass with a surface coating: low-emissivity, solar control and self-cleaning coatings.

Every standard and regulation we work to, explained

Documents

The specification sheet carries this page's content with today's catalogue figures, in three printable pages.

Cookies on this site

We use necessary cookies to make this site work.

With your consent, we'd also like to set functional, analytics and marketing cookies.

Read the cookie policy